Component qualification
Dimensions, tolerances, center of gravity, fragile features, lead condition and incoming package.
A feeder is only one link. Direction control, forming, presentation, nozzle geometry, mounting and signals must operate as one system.
FEED · ORIENT · FORM · PRESENTThe process changes with the package. Steps are added or removed after sample testing.
Dimensions, tolerances, center of gravity, fragile features, lead condition and incoming package.
Mounting envelope, pick coordinates, access, changeover, material refill and rejected-part handling.
24 V/220 V requirements, air supply, IO or self-control logic, alarms and responsibility boundaries.
The 2025 feeder catalog shows these project combinations. They demonstrate experience, not automatic compatibility with every model.
| Host platform | Catalog example | New project confirmation |
|---|---|---|
| Panasonic CM602 odd-form | Tube feeder + bowl feeder | Machine variant, mounting, signal and nozzle |
| Mirae odd-form | Tube + bowl + radial tape feeder | Pick position, clearance and component program |
| JUKI odd-form | Tube + bowl + radial tape feeder | Host model, communications and tooling |
| Yamaha odd-form | Tube feeder | Host model, physical interface and controls |
Recommended evidence includes a representative component batch, agreed target form, consecutive feed test, fault recovery checks, sample pick/insertion evidence and operator changeover review.
Define acceptance criteria